西安电子科技大学学报 ›› 2018, Vol. 45 ›› Issue (6): 86-91.doi: 10.3969/j.issn.1001-2400.2018.06.015

• 研究论文 • 上一篇    下一篇

一种快速高分辨率的VCO频率校准技术

蔡青松1,2;杨中1,2;贾晓云1,2;乔树山1,2;樊晓华1,2   

  1. (1. 中国科学院 微电子研究所,北京 100029;
    2. 中国科学院大学 电子电气与通信工程学院,北京 100049)
  • 收稿日期:2017-12-26 出版日期:2018-12-20 发布日期:2018-12-20
  • 作者简介:蔡青松(1991-), 男, 中国科学院微电子研究所博士研究生,E-mail:caiqingsong@ime.ac.cn
  • 基金资助:
    国家自然科学基金资助项目(61474135)

Fast and high-resolution VCO frequency calibration technique

CAI Qingsong1,2;YANG Zhong1,2;JIA Xiaoyun1,2;QIAO Shushan1,2;FAN Xiaohua1,2   

  1. (1. Institute of Microelectronics of Chinese Academy of Sciences, Beijing 100029, China;
    2. School of Electronic, Electrical and Comm. Eng., Univ. of Chinese Academy of Sciences Beijing, 100049)
  • Received:2017-12-26 Online:2018-12-20 Published:2018-12-20

摘要: 为了在不影响校准分辨率的情况下减小压控振荡器的频率校准时间,提出了一种拥有混合校准过程的频率校准技术.该校准技术先利用相对频率比较方法来检测和减小当前频率子带与目标频率的偏移量,当频率子带靠近目标频率时,再使用频率误差检测方法获得高精度的校准分辨率.凭借着快速相对频率比较过程和高精度频率误差检测过程,压控振荡器获得2MHz校准分辨率所需的时间仅为2.77μs.与传统频率误差检测技术相比,在相同校准分辨率的情况下,该技术的校准时间减少了31%.此外,该校准技术适用于多位宽开关电容阵列的分数频率综合器.

关键词: 压控振荡器频率校准, 混合校准过程, 校准分辨率, 校准时间, 频率综合器

Abstract: A frequency calibration technique with the hybrid calibration process is proposed to reduce the calibration time of the voltage-controlled oscillator (VCO) and maintain the fine calibration resolution. The calibration technique begins by employing the relative frequency comparison method to discern and decrease the difference between the frequency tuning curve and the target frequency. When the frequency tuning curve is close to the target frequency, the calibration technique changes to utilize the frequency error detection method to achieve a fine calibration resolution. With the fast relative frequency comparison process and the high-accuracy frequency error detection process, the calibration time for a frequency resolution of 2MHz is only 2.77μs. Compared to the conventional binary searcher process by only employing the frequency error detection method, the proposed technique saves 31% of the calibration time under the same calibration resolution. Furthermore, this calibration technique is suitable for the wideband fractional-N frequency synthesizer.

Key words: voltage controlled oscillator frequency calibration, hybrid calibration process, calibration resolution, calibration time, frequency synthesizer

中图分类号: 

  • TN911.8
Baidu